-- --defines FALCONF200-MIB for SNMP agent extension of Falcon F200 --Contents: Global Registration Module -- Falcon F200 OIDs - Enterprise 3184 --Version: 2.0.5 --Date: 31 Mar 2014 --Version: 2.0.6 --Date: 16 Nov 2015 --Change: unitMacId syntax changed to PhyAddress -- -- F200-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, IpAddress, Counter, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, PhysAddress FROM RFC1213-MIB; rle OBJECT IDENTIFIER ::= { enterprises 3184 } products OBJECT IDENTIFIER ::= { rle 1 } f200 OBJECT IDENTIFIER ::= { products 14 } productInfo OBJECT IDENTIFIER ::= { f200 1 } sensors OBJECT IDENTIFIER ::= { f200 2 } leakCables OBJECT IDENTIFIER ::= { f200 3 } digInputs OBJECT IDENTIFIER ::= { f200 4 } relays OBJECT IDENTIFIER ::= { f200 5 } f200Trap OBJECT IDENTIFIER ::= { f200 6 } sensor1 OBJECT IDENTIFIER ::= { sensors 1 } sensor2 OBJECT IDENTIFIER ::= { sensors 2 } sensor3 OBJECT IDENTIFIER ::= { sensors 3 } sensor4 OBJECT IDENTIFIER ::= { sensors 4 } relay1 OBJECT IDENTIFIER ::= { relays 1 } digInput1 OBJECT IDENTIFIER ::= { digInputs 1 } digInput2 OBJECT IDENTIFIER ::= { digInputs 2 } digInput3 OBJECT IDENTIFIER ::= { digInputs 3 } digInput4 OBJECT IDENTIFIER ::= { digInputs 4 } digInput5 OBJECT IDENTIFIER ::= { digInputs 5 } digInput6 OBJECT IDENTIFIER ::= { digInputs 6 } digInput7 OBJECT IDENTIFIER ::= { digInputs 7 } digInput8 OBJECT IDENTIFIER ::= { digInputs 8 } leak1 OBJECT IDENTIFIER ::= { leakCables 1 } -- Relay -- relay1State OBJECT-TYPE SYNTAX INTEGER { off(0), energized(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the relay. 1 = Energized, 0 = De-Energized" ::= { relay1 1 } -- Digital Inputs -- ---------------------------------------------------------------------- digInput1State OBJECT-TYPE SYNTAX INTEGER { open(0), closed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of Digital Input #1. 1 = Closed, 0 = Open" ::= { digInput1 1 } digInput1Alarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of Digital Input #1. 1 = Closed, 0 = Open" ::= { digInput1 2 } digInput2State OBJECT-TYPE SYNTAX INTEGER { open(0), closed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of Digital Input #2. 1 = Closed, 0 = Open" ::= { digInput2 1 } digInput2Alarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of Digital Input #2. 1 = Closed, 0 = Open" ::= { digInput2 2 } digInput3State OBJECT-TYPE SYNTAX INTEGER { open(0), closed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of Digital Input #3. 1 = Closed, 0 = Open" ::= { digInput3 1 } digInput3Alarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of Digital Input #3. 1 = Closed, 0 = Open" ::= { digInput3 2 } digInput4State OBJECT-TYPE SYNTAX INTEGER { open(0), closed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of Digital Input #4. 1 = Closed, 0 = Open" ::= { digInput4 1 } digInput4Alarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of Digital Input #4. 1 = Closed, 0 = Open" ::= { digInput4 2 } digInput5State OBJECT-TYPE SYNTAX INTEGER { open(0), closed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of Digital Input #5. 1 = Closed, 0 = Open" ::= { digInput5 1 } digInput5Alarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of Digital Input #5. 1 = Closed, 0 = Open" ::= { digInput5 2 } digInput6State OBJECT-TYPE SYNTAX INTEGER { open(0), closed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of Digital Input #6. 1 = Closed, 0 = Open" ::= { digInput6 1 } digInput6Alarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of Digital Input #6. 1 = Closed, 0 = Open" ::= { digInput6 2 } digInput7State OBJECT-TYPE SYNTAX INTEGER { open(0), closed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of Digital Input #7. 1 = Closed, 0 = Open" ::= { digInput7 1 } digInput7Alarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of Digital Input #7. 1 = Closed, 0 = Open" ::= { digInput7 2 } digInput8State OBJECT-TYPE SYNTAX INTEGER { open(0), closed(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of Digital Input #8. 1 = Closed, 0 = Open" ::= { digInput8 1 } digInput8Alarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } ACCESS read-only STATUS mandatory DESCRIPTION "The alarm state of Digital Input #8. 1 = Closed, 0 = Open" ::= { digInput8 2 } -- Leak Cable -- --------------------------------------------------------------- leak1CableFound OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This indicates that a cable is connected to the unit, even if leak detection is disabled. 1=Conneced, 0=No Cable" ::= { leak1 1 } leak1Current OBJECT-TYPE SYNTAX INTEGER (0..200) ACCESS read-only STATUS mandatory DESCRIPTION "The current conducting through the leak cable in uA" ::= { leak1 2 } leak1Alarm OBJECT-TYPE SYNTAX INTEGER { noLeak(0), leakDetected(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This is set to 1 when a leak is detected" ::= { leak1 3 } leak1CableBreak OBJECT-TYPE SYNTAX INTEGER { cableNormal(0), cableBreakDetected(1) } ACCESS read-only STATUS mandatory DESCRIPTION "This value get set to 1 if one of the loops in the cable is broken" ::= { leak1 4 } -- Product Info -- ------------------------------------------------------------------------ firmwareVersion OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current firmware version for this product" ::= { productInfo 1 } unitName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The name of this unit as defined by the user in the user interface" ::= { productInfo 2 } unitMacID OBJECT-TYPE SYNTAX PhysAddress ACCESS read-only STATUS mandatory DESCRIPTION "The MAC ID of the unit" ::= { productInfo 3 } unitSerial OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The RLE serial number for this unit" ::= { productInfo 4 } -- Sensors -- ------------------------------------------------------------------------ sensor1Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "User defined name of sensor attatched to port #1" ::= { sensor1 1} sensor2Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "User defined name of sensor attatched to port #2" ::= { sensor2 1} sensor3Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "User defined name of sensor attatched to port #3" ::= { sensor3 1} sensor4Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "User defined name of sensor attatched to port #4" ::= { sensor4 1} sensor1Location OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "User defined location of sensor attatched to port #1" ::= { sensor1 2} sensor2Location OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "User defined location of sensor attatched to port #2" ::= { sensor2 2} sensor3Location OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "User defined location of sensor attatched to port #3" ::= { sensor3 2} sensor4Location OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "User defined location of sensor attatched to port #4" ::= { sensor4 2} sensor1Type OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Type of Sensor attatched to Port 1" ::= { sensor1 3} sensor2Type OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Type of Sensor attatched to Port 2" ::= { sensor2 3} sensor3Type OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Type of Sensor attatched to Port 3" ::= { sensor3 3} sensor4Type OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Type of Sensor attatched to Port 4" ::= { sensor4 3} sensor1Temperature OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Temperature reading of sensor on Port 1 in Degrees Celsius multiplied by 100" ::= { sensor1 4} sensor2Temperature OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Temperature reading of sensor on Port 2 in Degrees Celsius multiplied by 100" ::= { sensor2 4} sensor3Temperature OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Temperature reading of sensor on Port 3 in Degrees Celsius multiplied by 100" ::= { sensor3 4} sensor4Temperature OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Temperature reading of sensor on Port 4 in Degrees Celsius multiplied by 100" ::= { sensor4 4} sensor1Humidity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Percent relative humidity read by sensor on Port 1" ::= { sensor1 5} sensor2Humidity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Percent relative humidity read by sensor on Port 2" ::= { sensor2 5} sensor3Humidity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Percent relative humidity read by sensor on Port 3" ::= { sensor3 5} sensor4Humidity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Percent relative humidity read by sensor on Port 4" ::= { sensor4 5} sensor1MaxTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum temperature alarm point for sensor on Port 1 in Degrees Celsius multiplied by 100" ::= { sensor1 6} sensor2MaxTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum temperature alarm point for sensor on Port 2 in Degrees Celsius multiplied by 100" ::= { sensor2 6} sensor3MaxTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum temperature alarm point for sensor on Port 3 in Degrees Celsius multiplied by 100" ::= { sensor3 6} sensor4MaxTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum temperature alarm point for sensor on Port 4 in Degrees Celsius multiplied by 100" ::= { sensor4 6} sensor1MinTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minimum temperature alarm point for sensor on Port 1 in Degrees Celsius multiplied by 100" ::= { sensor1 7} sensor2MinTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minimum temperature alarm point for sensor on Port 2 in Degrees Celsius multiplied by 100" ::= { sensor2 7} sensor3MinTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minimum temperature alarm point for sensor on Port 3 in Degrees Celsius multiplied by 100" ::= { sensor3 7} sensor4MinTemp OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minimum temperature alarm point for sensor on Port 4 in Degrees Celsius multiplied by 100" ::= { sensor4 7} sensor1MaxHumidity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum Humidity alarm point for sensor on Port 1" ::= { sensor1 8} sensor2MaxHumidity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum Humidity alarm point for sensor on Port 2" ::= { sensor2 8} sensor3MaxHumidity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum Humidity alarm point for sensor on Port 3" ::= { sensor3 8} sensor4MaxHumidity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum Humidity alarm point for sensor on Port 4" ::= { sensor4 8} sensor1MinHumidity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minimum Humidity alarm point for sensor on Port 1" ::= { sensor1 9} sensor2MinHumidity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minimum Humidity alarm point for sensor on Port 2" ::= { sensor2 9} sensor3MinHumidity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minimum Humidity alarm point for sensor on Port 3" ::= { sensor3 9} sensor4MinHumidity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Minimum Humidity alarm point for sensor on Port 4" ::= { sensor4 9} sensor1AlarmStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Alarm status for port 1. 1=In Alarm, 0=Normal" ::= { sensor1 10} sensor2AlarmStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Alarm status for port 2. 1=In Alarm, 0=Normal" ::= { sensor2 10} sensor3AlarmStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Alarm status for port 3. 1=In Alarm, 0=Normal" ::= { sensor3 10} sensor4AlarmStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Alarm status for port 4. 1=In Alarm, 0=Normal" ::= { sensor4 10} --digitalInAlarm Traps ------------------------------------------------------- digitalIn1Alarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn1Alarm trap indicates that digital input 1 has either opened or closed to cause an alarm" ::= 1 digitalIn2Alarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn2Alarm trap indicates that digital input 2 has either opened or closed to cause an alarm" ::= 2 digitalIn3Alarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn3Alarm trap indicates that digital input 3 has either opened or closed to cause an alarm" ::= 3 digitalIn4Alarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn4Alarm trap indicates that digital input 4 has either opened or closed to cause an alarm" ::= 4 digitalIn5Alarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn5Alarm trap indicates that digital input 5 has either opened or closed to cause an alarm" ::= 5 digitalIn6Alarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn6Alarm trap indicates that digital input 6 has either opened or closed to cause an alarm" ::= 6 digitalIn7Alarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn7Alarm trap indicates that digital input 7 has either opened or closed to cause an alarm" ::= 7 digitalIn8Alarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn8Alarm trap indicates that digital input 8 has either opened or closed to cause an alarm" ::= 8 --digitalInNormal Traps ------------------------------------------------------- digitalIn1Normal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn1Normal trap indicates that digital input 1 has returned to normal" ::= 9 digitalIn2Normal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn2Normal trap indicates that digital input 2 has returned to normal" ::= 10 digitalIn3Normal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn3Normal trap indicates that digital input 3 has returned to normal" ::= 11 digitalIn4Normal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn4Normal trap indicates that digital input 4 has returned to normal" ::= 12 digitalIn5Normal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn5Normal trap indicates that digital input 5 has returned to normal" ::= 13 digitalIn6Normal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn6Normal trap indicates that digital input 6 has returned to normal" ::= 14 digitalIn7Normal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn7Normal trap indicates that digital input 7 has returned to normal" ::= 15 digitalIn8Normal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn8Normal trap indicates that digital input 8 has returned to normal" ::= 16 --digitalInOpened Traps ------------------------------------------------------- digitalIn1Opened TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn1Opened trap indicates that digital input 1 has just been Opened" ::= 17 digitalIn2Opened TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn2Opened trap indicates that digital input 2 has just been Opened" ::= 18 digitalIn3Opened TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn3Opened trap indicates that digital input 3 has just been Opened" ::= 19 digitalIn4Opened TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn4Opened trap indicates that digital input 4 has just been Opened" ::= 20 digitalIn5Opened TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn5Opened trap indicates that digital input 5 has just been Opened" ::= 21 digitalIn6Opened TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn6Opened trap indicates that digital input 6 has just been Opened" ::= 22 digitalIn7Opened TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn7Opened trap indicates that digital input 7 has just been Opened" ::= 23 digitalIn8Opened TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn8Opened trap indicates that digital input 8 has just been Opened" ::= 24 --digitalInClosed Traps ------------------------------------------------------- digitalIn1Closed TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn1Closed trap indicates that digital input 1 has just been Closed" ::= 25 digitalIn2Closed TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn2Closed trap indicates that digital input 2 has just been Closed" ::= 26 digitalIn3Closed TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn3Closed trap indicates that digital input 3 has just been Closed" ::= 27 digitalIn4Closed TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn4Closed trap indicates that digital input 4 has just been Closed" ::= 28 digitalIn5Closed TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn5Closed trap indicates that digital input 5 has just been Closed" ::= 29 digitalIn6Closed TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn6Closed trap indicates that digital input 6 has just been Closed" ::= 30 digitalIn7Closed TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn7Closed trap indicates that digital input 7 has just been Closed" ::= 31 digitalIn8Closed TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A digitalIn8Closed trap indicates that digital input 8 has just been Closed" ::= 32 --leakDetected Traps ------------------------------------------------------- leakDetected TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A leakDetected trap indicates a leak has been detected on the cable" ::= 33 --leakCleared Traps ------------------------------------------------------- leakCleared TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A leakCleared trap indicates a leak is no longer detected" ::= 34 --leakCableBreak Traps ------------------------------------------------------- leakCableBreak TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A leakCableBreak trap indicates a leak cable has been disconnected or broken" ::= 35 --leakCableConnected Traps ------------------------------------------------------- leakCableConnected TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A leakCableConnected trap indicates a leak cable has been connected or repaired" ::= 36 --sensorTempAlarm Traps ------------------------------------------------------- sensor1TempAlarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A sensor1TempAlarm trap indicates the temperature has exceeded the given range" ::= 37 sensor2TempAlarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A sensor2TempAlarm trap indicates the temperature has exceeded the given range" ::= 38 sensor3TempAlarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A sensor3TempAlarm trap indicates the temperature has exceeded the given range" ::= 39 sensor4TempAlarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A sensor4TempAlarm trap indicates the temperature has exceeded the given range" ::= 40 --sensorTempNormal Traps ------------------------------------------------------- sensor1TempNormal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A sensor1TempNormal trap indicates the temperature has returned to the given range" ::= 41 sensor2TempNormal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A sensor2TempNormal trap indicates the temperature has returned to the given range" ::= 42 sensor3TempNormal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A sensor3TempNormal trap indicates the temperature has returned to the given range" ::= 43 sensor4TempNormal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A sensor4TempNormal trap indicates the temperature has returned to the given range" ::= 44 --sensorHumidityAlarm Traps ------------------------------------------------------- sensor1HumidityAlarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A sensor1HumidityAlarm trap indicates the humidity is out of range" ::= 45 sensor2HumidityAlarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A sensor2HumidityAlarm trap indicates the humidity is out of range" ::= 46 sensor3HumidityAlarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A sensor3HumidityAlarm trap indicates the humidity is out of range" ::= 47 sensor4HumidityAlarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A sensor4HumidityAlarm trap indicates the humidity is out of range" ::= 48 --sensorHumidityNormal Traps ------------------------------------------------------- sensor1HumidityNormal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A sensor1HumidityNormal trap indicates the humidity has returned to within range" ::= 49 sensor2HumidityNormal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A sensor2HumidityNormal trap indicates the humidity has returned to within range" ::= 50 sensor3HumidityNormal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A sensor3HumidityNormal trap indicates the humidity has returned to within range" ::= 51 sensor4HumidityNormal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A sensor4HumidityNormal trap indicates the humidity has returned to within range" ::= 52 --relayClosed Traps ------------------------------------------------------- relay1Closed TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A relay1Closed trap indicates the relay has been energized (Closed)" ::= 53 --relayOpened Traps ------------------------------------------------------- relay1Opened TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A relay1Opened trap indicates the relay has been energized (Opened)" ::= 54 --f200Alarm Traps ------------------------------------------------------- f200Alarm TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A f200Alarm trap indicates the F200 has at least one alarm" ::= 55 --f200Normal Traps ------------------------------------------------------- f200Normal TRAP-TYPE ENTERPRISE f200Trap VARIABLES { unitName } DESCRIPTION "A f200Normal trap indicates the F200 has returned to normal, ther are no alarms" ::= 56 END