Building pressure is the difference between the outside air supplied to a building and the air removed from inside a building. Typically, facilities managers are trying to achieve a building with slight positive building pressure, meaning more air is supplied to the building than is removed from the building.
Negative Pressure Indicators
Negative building pressure means outside air is constantly being drawn into a building. This can cause discomfort to inhabitants, but worse, negative pressure can also pull airborne particles in to places you don’t want them. How do you know if your building has negative pressure? If you’re not currently using sensors to monitor your facility there are some environmental indicators that point toward negative building pressure:
- Difficulty Opening Doors: Difficulty opening doors is a leading indicator of negative pressure in a building. If you have to use extra muscle to wrench open doors, you may have a negative pressure issue.
- High Humidity: A negatively pressurized building will pull unconditioned outside air in through any possible opening, which can lead to condensation and mold, especially in the summer months when humidity is high.
- Outside Contamination: Negatively pressurized facilities are more likely to collect outside debris. Bugs, leaves and even smells can pollute a negatively pressured indoor environment.
- Hot / Cold Spots: The collision and separation of building pressures can create hot or cold spots based on how the air is being forced to behave.
- High Energy Costs: If negative pressure is pulling outside air into your facility, you’re constantly using energy to condition incoming air.
Monitoring to Track Positive Pressure
At RLE, we believe monitoring facility pressure shouldn’t be left to guesswork. That’s why we’ve expanded our wireless WiNG monitoring platform to include the WiNG-DAP, a differential air pressure sensor that can be deployed anywhere in a building to help optimize building system operation. Leverage the WiNG-MGR, WiNG-DAP, and our complete suite of wireless WiNG sensors and transmitters for facility monitoring and reporting, or integrate them into a BMS for additional controls opportunities.
Article contributed by Michael Hadt.

Poudre P-TECH Visits RLE Technologies
P-TECH (Pathway in Technology Early College High School) schools have seen success in Colorado since the program was first introduced in 2015. In a P-TECH school, students gain relevant work experience while they earn both a high school diploma and a tuition-free…
Services Success Case Study
Long-Term Relationships Are The Key To Success BROGAV Solutions, an adept and skilled sourcing partner of RLE Technologies, had a client who required leak detection products to be installed in a new white space area. The primary goal was to safeguard the space and…

CO2 Monitoring To Help You Thrive
Carbon dioxide (CO2) has emerged as an important air quality metric. But why do we monitor CO2? We monitor CO2 so that we can track optimal conditions, helping people and plants thrive. Let’s look at two very different ends of the CO2 spectrum.

Product Advisory – Grey Flek
Dear Valued Customer, It has recently come to our attention that we are no longer able to source our original “Grey Flek” color powder coat which has been our standard gray-colored powder coat since the origin of our Triad floor panel products. After working with…
Firmware Update – LD5200
New firmware has been released for the LD5200. Firmware files are available on our Firmware Updates and MIB Files page. Firmware Updates and MIB Files page Firmware Release Notes – LD5200

Configuring EIA-485 for Modbus and BACnet
EIA-485 (formerly known as RS-485 or RS485) is a specification for the physical layer of a network that uses the difference in voltages between 2 wires. Simply, if one wire is high (digital 1) the other will be low (digital 0), and vice versa. This simplicity allows…
Firmware Update – WiNG-MGR
New firmware has been released for the WiNG-MGR. Firmware files are available on our Firmware Updates and MIB Files page. Firmware Updates and MIB Files page Firmware Release Notes – WiNG-MGR
Firmware Update – WiNG-MGR v2
New firmware has been released for the WiNG-MGR v2. Firmware files are available on our Firmware Updates and MIB Files page. Firmware Updates and MIB Files page Firmware Release Notes – WiNG-MGR v2
Comprehensive Leak Detection Systems
Comprehensive Leak Detection Systems for Sustainable Data Center Resiliency We recently collaborated with industry experts and our partner DP Guardian to craft messaging about the importance of complete coverage in avoiding data center downtime. Read the white paper…
Frequency Expansion of WiNG Product Line
The 865MHz Frequency Builds On The Success Of The 900MHz, And 868MHz Range For WiNG RLE Technologies, a leading provider of patented raised floors and containment, leak detection systems, and remote monitoring solutions for mission-critical facilities has expanded its…